Requirement: S.17 Corrective Action

Attributes
Created Thursday, November 19, 2009 at 08:42:39 PM
Creator University User
Description If the control system determines the adjustments need to be made, then the computer shall direct the system to raise or lower the power to the pumps until the optimum conditions are met.
Key Performance Parameter false
Last Modified Saturday, November 21, 2009 at 12:13:05 PM
Number S.17
Origin Derived
Paragraph Title Subsystem Requirements
Rationale Requirements decomposed from the system level OTEC requirements
Title OTEC Control Subsystem
Type Performance
Relationships
basis of Function 1 Control OTEC System
documented by Document Requirements, Codes, Standards, and Regulations
refines Requirement N.1 Command
Requirement N.3 Monitoring and Control
specifies Component 1 Central Computer